| DC Voltage
& Current |
Accuracy
Protection |
± 0.1% ±
1 count, typical; ± 0.2% ± 1 count, max.
mV DC:
200V continuous, 350V intermittent.
V dc: 350 continuous, 500VV intermittent.
DC current shunt: 5V max. |
|
DC Current Shunt |
Accuracy
Protection |
± 0.1% ±
1 count, typical;
± 0.2% ± 1 count, max.
mV DC:
200V continuous, 350V intermittent.
V dc: 350V continuous, 500V intermittent.
5 V max |
|
Process Signal (4-20 mA) |
Protection
Burden
Accuracy |
100 mA
DC
2.2 V
max with revere current protection.
± 0.1% ±
1 count, typical; ± 0.2% ± 1 count, max. |
|
Loop-Powered Process Signal (4-20 mA) |
Protection
Burden
Accuracy |
30 mA
forward, 75 mA reverse
240 mV @
20 mA
± 0.1% ±
1 count |
|
Process Signal (1-5 V) |
Protection
Burden
Accuracy |
200V
continuous, 250V intermittent.
2.2V
max with revere current protection.
± 0.1% ±
1 count, typical; ± 0.2% ± 1 count, max. |
|
AC TRMS Voltage & Current |
Accuracy
Protection
Resistance |
± 0.5% ±
1 count, typical; ± 0.2% ± 1 count, max.
AC
Volts: 350V continuous, 500V intermittent.
AC current: 300% of full scale. 2A & 5A scales: 120% of full scale.
1 MOhm |
|
Scaling (Process, AC RMS,
DC Isolated Inputs) |
| Full
Scale Span Adjustment |
Coarse
adjustment: four ranges set by DIP switch:.
100-400 counts, 400-800 counts, 800-1500 counts,
1500-2000 counts |
| Fine
Span Adjustment |
25-turn
potentiometer |
| Zero
Offset Adjustment |
25-turn
potentiometer
± 15% of full scale (process input)
± 10% of full scale (AC TRMS input) |
|
Scaling (Loop-Powered
Process, DC Shunt, DC Non-Isolated Inputs) |
| Full
Scale Span Adjustment |
Coarse adjustment: four ranges set by DIP switch:
100-250 counts, 250-500 counts, 500-1000 counts,
1000-2000 counts |
| Fine
Span Adjustment |
25-turn
potentiometer |
Zero
Offset Adjustment
(loop-powered process only) |
Three
choices set by DIP switch:
-20% to +20% of span
True zero ( 4 mA DC = 20 mA of span)
+20% to +60% of span
Fine adjustment via 25-turn potentiometer |
|
Display |
Number of Digits
Display Type
Digit Height
Signal Polarity
Overload Indication
Decimal Point
LCD
Backlight Options |
3½ (±1999 counts)
7-segment LCD with
backlight option
0.50" (12.7 mm)
Automatic, minus sign
displayed
Three lower order
digits blank for > 1999 counts
Three positions,
switch selectable
Non-backlit, Red negative, Red positive, Green negative
Green positive, Orange negative |
|
Electrical Performance |
Conversion Rate
Normal Mode Rejection
Common Mode Rejection
Power
Options
Power
Consumption
Warm-up
time |
2.5 readings / second
30 dB @ 60 Hz
> 86 dB
115 &
230 V AC, 50-60 Hz; 12 & 24 DC, isolated
10-15 V DC & 16-32 V DC, non-isolated
< 2 VA
at 115 V AC, < 3 VA at 230 V AC
105 mA with DC power and backlighting
10 minutes (typical) |
|
Environmental |
Operating Temperature
Storage Temperature |
0 to 40°C
standard, -20 to 60°C optional
-10 to 60°C
standard, -30 to 70°C optional |