42213 Sarah Way, Temecula, CA 92590,
USA |
Tel: 800-854-8530 (USA)
Tel: 951-699-2437
Fax: 951-695-7246
sales@electronumerics.com |
 |
Micro Series Pulse Input
Batch Controllers
With three relay outputs for automated batch
control
Features
- Available in three digit heights:
0.56" for panel mounting,
1.0" (Mighty-1) or
5.0" (Mighty-5) for
long-distance viewing.
- 6-digit display scalable to
±999,999
- Selectable display of batch
total, grand total
or number of batches, and rate.
- Single 8A relay for batch
total, with settable delay between cycles.
- Two optional additional relays
assignable to batch total for prewarn, grand total or number of batches, and rate.
- Count up from 0 to
preset or
down from preset to 0.
- Frequency input from 0 Hz to
1
MHz.
- Signals from turbine flowmeters,
magnetic pickups, NPN or PNP transistors, digital logic, or AC from 12 mV to 250 Vac.
- Selectable "count by"
of 10 or 100 with rounding.
- Isolated 5, 10 or 24 Vdc
excitation supply to power sensors.
- Choice of isolated plug-in
options for control and computer interface:
dual
relays,
4-20 mA & 0-10
V analog output,
RS-232/485 serial I/O,
low voltage AC & DC power.
-
1/8 DIN
version environmentally sealed to NEMA-4X from front panel.
- 1/8 DIN
version certified to UL 3101-1, CAN/CSA-C22.2,
EN 61010-1 (CE Mark).
|

Description
The
Micro Series batch controller is a powerful and highly accurate production
workhorse in the form of a compact 1/8 DIN panel meter. It can display the current batch
total (Item #1), grand total or number of batches (Item #2), and flow rate (Item #3). All
displayed values are scaled to engineering units of volume or flow.
The batch controller utilizes the Extended
counter main board and FR dual channel signal conditioner board to accept a wide range of
pulse signals, in particular those from turbine flowmeters. The same signal is applied in
parallel to the A and B channels.
A 8A contact relay serves as the batch relay to control repetitive fill operations.
It repeats the batch cycles continually with a programmable delay from 10 ms to 199.99
sec, or based on an external control input. The batch total (Item #1) can be set up to
count up from zero to a preset limit, or down from a preset limit to zero. The
single-relay board fits in the slot which would otherwise be available for the analog
output board.
An optional dual relay board (8A contact or 0.12 A AC/DC solid state
relays) is normally used. Either relay can be assigned to the batch total (Item #1) to
serve as a pre-warn to slow down filling near the setpoint, to the grand total or number
of batches (Item #2), or to flow rate (Item #3).
An optional RS-232 or RS-485 board allows the batch controller to transmit
Items #1, #2 and #3, as well as peak for #3 (rate). If required, all four items can be
displayed simultaneously by augmenting the batch controller with up to three
Micro 1/8 DIN
remote displays. Each of these can have its own analog output and dual relays for alarm or
control.
Fast, High Accuracy
Measurement
The A and B channels of the FR
dual-channel signal conditioner are used independently. Either channel can accept pulse
rates from 0.005 Hz to 250 kHz, which exceeds the working range of turbine
flow meters.
Channel A is used for
totalizing. The measured total is scaled mathematically for control and display in
engineering units, such as liters.
Channel B is used for rate.
The pulse frequency is determined by timing an integral number of periods over a specified
gate time (plus 30 ms and 0-2 periods), and then taking the inverse of period. The inverse
period approach allows much greater accuracy and faster update times than conventional
rate meters which count signal pulses over a specified time interval. Update times can be
as high as 25/sec. Rate in engineering units, such as liters per second, is obtained by
multiplying the input by a scale factor.
For either total or rate, displayed values can
be up to six digits (999,999) with a selectable decimal point.
Flowmeter Signal Conditioner
The FR dual-channel signal
conditioner accepts pulses from all types of turbine flowmeters and most industrial
transducers with a pulse output such as proximity switches with PNP or NPN output, TTL or
CMOS logic, magnetic pickup pulses down to 12 mV, as well as AC inputs up to 250 Vac. Jumper
selections provide optimum operation for different sensor types and noise
conditions.
A built-in isolated 5, 10, or 24 Vdc
excitation supply can power proximity switches and other sensors, and eliminate the need
for an external power supply.
Built-in Flexibility
Micro Series
batch controller can be powered from
95-240 Vac ±10% and 95-370 Vdc, or
optionally from 12-34 Vac and 10-48 Vdc.
Any setup functions and front panel keys may be locked out for
simplified usage and security. The ability of the Micro batch controller
to drive an isolated 4-20 mA or 0-10 V output signal which tracks a
total may be unique among batch controllers.
The popular
1/8
DIN version with 0.56" high digits is environmentally sealed to
NEMA-4X (IP65) from the front when panel mounted, and is
available with red or green LEDs. All power and signal
connections are via UL / VDE / CSA rated screw clamp plugs,
which are standard.
|

Specifications
|
Display |
Readout
Digit Height
Color
Range
Indicators |
6 digits, 7-segment
Available with 0.56", 1.0", 4.0" or 5.0" digits.
High brightness red. Green available with 0.56" digits.
-999999 to +999999,
XXXXEX scientific notation beyond 999999
Four LED lamps |
|
Inputs |
Types
Signal ground
Channel A Frequency
Channel B Frequency
Selectable Hysteresis
Rolloff Filter
Debounce Time |
Pulses
from NPN, PNP transistors, contact closures, magnetic pickups, AC
Common ground for channels A & B
0 Hz to 1 MHz (totalizing), 0.005 Hz to 1 MHz (rate)
0 Hz to 250 kHz (totalizing), 0.005 Hz to 250 kHz (rate)
-12 mV to +12 mV, +30 mV to +60 mV, -30 mV to -20 m),
-150 mV to +150 mV, +350 mV to +600 mV, -600 mV to -350 mV,
-1.15V to
+1.15V, +1.25V to +2.1V, -2.1V to -1.25V
Selectable: 1 MHz, 30 kHz or 250 Hz
Selectable: 0, 3, 50 ms |
|
Rate
Conversion |
Frequency
Technique
Delay between batches
Display Update Time
Output Update Time |
Inverse period
Selectable 10 ms to 199.99 s
Same as conversion time
Same as conversion time |
|
Rate
Accuracy |
Time Base
Span Tempco
Long-term Drift |
Crystal
calibrated to ±2 ppm
±1 ppm/°C (typ)
±5 ppm/year |
|
Power |
Voltage,
std.
Voltage, opt.
Frequency
Power isolation |
95-240 Vac ±10% and 95-370 Vdc
12-34 Vac and 10-48 Vdc
DC or 49-440 Hz
Safety-rated to 250 Vac, meter ground to earth ground,
DC to 60 Hz, 4.2 kVp per High Voltage Test |
|
Excitation Output |
5
Vdc
10 Vdc
24 Vdc
Output isolation |
5
Vdc ±5%, 100 mA max
10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
50 Vdc to meter ground |
|
Environmental |
Operating Temp.
Storage Temp.
Relative Humidity
Protection |
0°C to 60°C
-40°C to 85°C
95% at 40°C, non-condensing
NEMA-4X (IP-65) when panel mounted |
|
Electrical Connections |
 |

|
Typical
Applications |
Drum Filling Application Utilizing Three Relay Outputs |
 |
In this drum filling application, the Micro
batch controller utilizes
its maximum of three relays to control the pump. The
Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay
stops the pump at the preset. The Grand Total relay stops the filling operation once a
predetermined number of drums have been filled. |
Controlling the Mixing of Materials |
 |
Multiple Micro batch controllers can be used in
combination to control the mixing of materials in the proper ratio. Each feed line is
equipped with its own pump, flowmeter, and Micro batch controller. Controller
setup and monitoring of the mixing operation are facilitated by optional serial
communications. RS-485 allows a single data line to handle multiple controllers. |
Up-Counting Batch Control |
 |
In up-counting batch control, the Micro
batch controller counts up from
zero to a preset maximum. A prewarn level is available to slow down filling near the
preset to avoid overshoot. A time delay can be programmed from the end of each batch to
the start of the next batch. |
Down-Counting Batch Control |
 |
In down-counting batch control, the Micro
batch controller counts down
from the preset maximum to zero. A prewarn level is available to slow down filling or
emptying near zero. Again, a time delay can be programmed from the end of each batch to
the start of the next batch. |
Discrete Filling and Batch Counting |
 |
The Micro batch controller is ideal for discrete
manufacturing as well as repetitive fill operations. In this example, the
Micro counts
bottles which it then groups into sixpacks. Its Grand Total capability can be used to
track bottles or sixpacks. |

Micro & Mighty Series Downloads
|